Inspection Coverage
389 mm (15.3″) wide at the belt, 237 mm (9.3″) wide at the top of aperture; 158 mm (6.2″) overall height
-
Inspection Modes
SimulTask™ 4 PRO standard inspection modes include contaminant, bone, missing item, clip, void, premium, shape/size, position, fill level, count, zonal mass, mass measurement with 2, 3, or 5 zone checkweighing functionality with statistics
-
User Interface & Operating System
15″ TFT color touch screen; Windows 10 Enterprise LTSB with Eagle SimulTask™ 4 PRO Control & Imaging Software; TeamViewer™ service tool for remote machine diagnostics & product set-up services
-
Conveyor Size
498 mm (19.6″) wide belt by 1829 mm (72″) long with no reject; 2438 mm (96″) long with 1 reject; 2895 mm (114″) long with 2 rejects; Blue food-grade belt compliant for transport of unpackaged foodstuffs
-
Reject Mechanism
24 VDC Signal only, airblast, push arm, custom rejects
-
Speed Range
15 – 61 MPM (50 – 200 FPM), subject to generator & detector used, product type & dimensions
-
X-ray Power
Single vertical beam; 100W (84kV, 1.2mA), 110W (110kV, 1mA), 330W (110kV, 3mA) or 420W (84kV, 5mA)
-
Detector Resolution
0.4 mm, 0.8 mm, 1.2 mm single energy, 1.2 mm MDX™ dual energy or PXT™ Performance X-ray Technology
-
Communication
(2) USB 2.0 ports, (1) Ethernet 10/100/1000 mbps port, (1) RS232 serial port; (1) EtherNet/IP Fieldbus interface port optional
-
IP Rating & Machine Finish
IP69 Standard; Type 304 Stainless Steel, #4 surface finish less than 32u-inch RA
-
Radiation Safety
X-ray emissions <1 uS/hr; compliant to 21 CFR 1020.40, 21 CFR 179.21, & EURATOM EU nationalized standards
-
Electrical Safety
X-ray emissions <1 uS/hr; compliant to 21 CFR 1020.40, 21 CFR 179.21, & EURATOM EU nationalized standards
-
Electrical Safety
Compliant with CAT-3 (EN954), PLd (EN13849) safety circuits with system visualization
-
Thermal Management
Water cooled heat exchanger, plant water supply ≥7.6LPM, 13°C to 21°C required; Optional air conditioner externally mounted
-
Operating Range
0°C to 40°C (32°F to 104°F) 25% to 90% relative humidity non-condensing
-
Power Requirements
230 VAC, +/-10%, Single Phase, 50/60 Hz, 16 Amp Fused
-
Options & Accessories
Multilane operation, product guides, reject bins; reject verify, bin full, counter-check, & package back-up sensors; audible & visual alarms; parts cart for cleaning, EtherNet/IP interface, TraceServer™ data collection software; RECON™ rework station, remote user interface, hazard based risk assessment